주요 메뉴 바로가기 보조 메뉴 바로가기 본문 바로가기
RESEARCH COMMUNICATION PORTAL

논문 국내 국내전문학술지(KCI급) AN EXPERIMENTAL STUDY ON THE EVALUATION OF SHEAR PERFORMANCE OF PVA FIBER REINFORCED RC DEEP BEAM WITH HIGH STRENGTH HEADED REBAR

  • 학술지 구분 국내전문학술지(KCI급)
  • 게재년월 2017-12
  • 저자명 김승훈
  • 학술지명 ARCHITECTURAL RESEARCH
  • 발행처명 대한건축학회
  • 발행국가 국내
  • 논문언어 외국어
  • 전체저자수 3

논문 초록 (Abstract)

This study is done to evaluate how existence of shear-span ratio and shear reinforcing bar effects on shear performance from through shea r experiment using PVA fiber reinforced ferroconcrete building. Ratio of shear-span was set 1, 1.7, and arrangement of shear reinforcing bar was set with KCI2012 regulation. In result, subject with less shear-spa n ratio, and shear reinforcing bar with arrangement of bar shows high stiffness. Subjects with high shear-span ratio show large differenc e dependingon existence of shear reinforcing bar. Therefore, theoret ical shear strength followed by CEB code underestimates experimental she ar strength by 43.9%. Shear strength of the deep beam with headed bars is more affected by the bearing strength of head than the bond strengt h of bar.