논문 해외 국제전문학술지(SCI급) Room-temperature rapid oxygen monitoring system in high humidity hydrogen gas environment towards water electrolysis application

fig
  • 학술지 구분 국제전문학술지(SCI급)
  • 게재년월 2025-01
  • 저자명 Yeongjae Kwon, Kichul Lee, Mingu Kang, Cheolmin Kim, Ji-Hwan Ha, Hyeonseok Han, Seungki Yang, Daejong Yang, Jung Hwan Seo, Inkyu Park
  • 학술지명 Sensors and Actuators B: Chemical
  • 발행국가 해외
  • 논문언어 외국어
  • 원문 링크 https://www.sciencedirect.com/science/article/abs/pii/S0925400524014230

논문 초록 (Abstract)

Water electrolysis is one of the key processes for carbon-free hydrogen (H2) generation, yet it inherently presents the risk of oxygen (O2) permeation, a significant concern that must be addressed. Contrary to external atmospheric conditions, the environment within a water electrolysis system is characterized exclusively by high-purity H2, little O2, and moisture (H2O). However, there has been limited research on sensors capable of detecting O2 crossover in such a pure H2 atmosphere under high humidity conditions. In this study, we developed an electrolysis O2 monitoring (E-OM) sensor based on a semiconducting metal oxide (SMO) that can operate at a room-temperature with such high humidity through photoactivation with 365 nm LED light. A porous In2O3 nanofilm, prepared by glancing angle deposition (GLAD), was used as the gas sensing material, and copper nanoparticles (Cu NPs) were decorated on the In2O3 surface through electron beam evaporation to accelerate the O2 adsorption. Remarkably, the E-OM sensor showed a humidity-independent response to O2 gas in the H2 atmosphere. Meanwhile, since the response of the E-OM sensor itself was not fast enough for water electrolysis system application, convolutional neural network (CNN)-based signal processing in the time domain was applied. As a result, our E-OM sensor system could predict O2 concentrations from 0 to 2 vol% in an H2 environment with a relative humidity (RH) of 30–90 %, and the detection time was under 5 s. This development could enable safe, rapid, and cost-effective monitoring of O2 crossover in H2 production infrastructure.